400 amp meter base with 2 200 amp disconnects - The 400 amp house panel unit is ideal for larger homes as well as apartments, condominiums, club houses or common areas that require meter breakers. Includes 1 ringless meter socket with lever bypass. Interrupt rating is 22 kAIC and the main breaker is the CSR2200.

 
Meter Pack, Ringless Style Meter Socket Covers, 1-Phase, 2 Meter Sockets, 200 Amp Socket Rating, 400 Amp Bus Rating, Aluminum Bus, Requires Bolt-on Type Main Tenant Circuit Breaker Also known as: 786685955605, 1MP2204RRLP Specifications Amps: 200, 400 Mounting: Surface Phase: 1 .... Uhaul somerdale nj

Hi guys I'm planning to feed two 200 amp main breaker panels from a 400 amp fused disconnect (Main disconnect after the meter provided by the building). If I ran all the wire to the disconnect load side lugs, am I still subject to the 25' tap rule? Thanks.Aug 7, 2023 · You can run a 320 amp service with 2 200 amp panels. It has to be either two separate disconnects or a sub-panel with one main disconnect. Running with a sub-panel is cheaper than using two separate disconnects. The 320 amps is a service ideal for residential 400 amp meter sockets. To meet this requirement, Milbank developed 400 Amps meter mains that include a single 400 Amps breaker disconnect and a meter socket in one enclosure. Our meter mains are good fits for large residential and commercial applications such as retail, office buildings and restaurants. Features: The wall-hanging bracket and side bussing are features ...Meter Pak, 2 Socket, 200 Amp, 4 Jaw, 400 Amp Bus, Ringed, 240 Volt AC, No Bypass, NEMA 3R, 1-Phase Also known as: 785901410409, MP42200 SpecificationsTo meet this requirement, Milbank developed 400 Amps meter mains that include a single 400 Amps breaker disconnect and a meter socket in one enclosure. Our meter mains are good fits for large residential and commercial applications such as retail, office buildings and restaurants. Features: The wall-hanging bracket and side bussing are features ... Up for sale is one brand new 400 / 320 AMP continuous, single phase meter base / meter socket which is not UL listed, plus two brand new 200A Square D main breakers / service disconnects NEC2020 compatible. This meter is a ringless type with lever bypass. For ring type meter, meter main / combo etc., please see my other lists. Jul 2, 2022 · I am installing a 400 amp meter base combo.I have seen plenty of example of 400 amp meter bases with separate 200 amp disconnects. These separate disconnects typically have a grounding bare and a hole punch to bring the grounding wire out through eco suit down to the grounding rods. This meter combo from milbank only has 2 large wholes to bring ... Meter Pak, 2 Socket, 200 Amp, 4 Jaw, 400 Amp Bus, Ringed, 240 Volt AC, No Bypass, NEMA 3R, 1-Phase Also known as: 785901410409, MP42200 SpecificationsRestoration and Rewiring of 100 year old post lamps. Lighted shower niches & seat. 400 Amp Residential Service. Converted grain bin to outdoor bar.Milbank Meter CAN Replacement Block Base Repair 200A for RINGLESS CANS with LUGS. 3.7 out of 5 stars. 4. $41.99 $ 41. 99. FREE delivery May 22 - 23 . Or fastest delivery May 16 - 20 . Add to cart- ... MILBANK 200 AMP 2 GANG METER U1252-R-KK-RGE WITH BYPASS HORNS RGE NEW. $700.00 $ 700. 00. FREE delivery May 22 - 23 . Or fastest …Electrical and Industrial | Power management solutions | EatonSquare D meter socket overhead/underground with 4-jaws. A-type hub provision and NEMA type 3R enclosure for outdoor use. Contact your local utility company to ensure requirements are met. 200 amp meter socket. Accommodates an overhead or underground feed. Suitable for use as service entrance equipment. Ringless design with no bypass. … Eaton 1011619CH 320 Amp Single Phase Meter Base Socket Ringless Lever Bypass 4 Terminal Factory Installed Lugs MEG Approved. $1,39350. FREE delivery Wed, May 22. Only 9 left in stock - order soon. The National Electrical Code (NEC) doesn’t prohibit installing two 200 Amp panels where 400-amp service is delivered to the residence. There are code differences depending on whether the installation includes a sub-panel or two independent disconnect panels.All manufacturers make an all in one 400 amp meter combo for residential. They are usually rated as 320 amp but they are really 400 amps non continuous load and 320 continuous load. Cutler Hammer , GE , Sq.D and Siemens all make them. They have 2 spaces inside for 2- 200 amp breakers and can also have some other spaces available for other loadsRe: Advice for a typical 400 amp residential service Typically, Ive seen parallels pulled from the meter base to two (2) 200 amp mcb panelboards in the basement. Why add all that cost, in addition, the outside wall of the residence wont look to pretty. Ever see a 400a meter base, quite hunky.If you have 2/0 Cu from the meter base to each 200 amp panel, even though it's widely accepted it is at times turned down with reason. It is a 175 amp conductor and the 310.15(B)(7) rule that allows it on a 200 amp panel only applies when then conductor is supplying the the entire load of the dwelling.A 100-amp main breaker panel receives 100-amp service at 240 volts. Electricity enters the home via the meter socket and service-entrance wire. Two-gauge, three-conductor aluminum ...SCHNEIDER ELECTRIC 600-Volt 400-Amp 3-Point Nema-3R HU365R Switch Nonfusible Hd 600V 400A 3P Nema3R. 1. $2,88631. List: $3,217.92. FREE delivery May 16 - 20. Or fastest delivery Wed, May 15.Jul 2, 2022 · I am installing a 400 amp meter base combo.I have seen plenty of example of 400 amp meter bases with separate 200 amp disconnects. These separate disconnects typically have a grounding bare and a hole punch to bring the grounding wire out through eco suit down to the grounding rods. This meter combo from milbank only has 2 large wholes to bring ... The Eaton 400 Amp 8-Space 16-Circuit Type BR Meter Socket and Main Breaker Load Center is ANSI certified and UL listed. The center is intended for use as a combination main breaker load center and meter socket for underground service applications. This unit is rated for service entrance equipment and has an aluminum buss. If you are a homeowner or business owner, you may have come across the term “double lug meter base” while researching your electrical system. A double lug meter base is an electric...Front accessible 4 or 5-jaw sockets with individual ring or ring less type meter covers. All unmetered bus is barbered and sealable to prevent unauthorized access. Galvanized …When you make a new account for any sort of web site or service, there’s usually a helpful-looking meter to tell how strong the password you came up with is. Don’t listen to those ...Hi guys I'm planning to feed two 200 amp main breaker panels from a 400 amp fused disconnect (Main disconnect after the meter provided by the building). If I ran all the wire to the disconnect load side lugs, am I still subject to the 25' tap rule? Thanks.Since then i had my PUD engineer come out and after a couple weeks the solution they came upwith was to install my 320 amp meter base and two 200 amp disconnects at the pole and then run an additional run of conduit to the house so my question now is do i need to pull the 500/500/350 and install 2 runs of 4 wire feeder to the panels at the ... Model # HPC40SHL. Get Pricing & Availability. Use Current Location. The 400 amp house panel unit is ideal for larger homes as well as apartments, condominiums, club houses or common areas that require meter breakers. Includes 1 ringless meter socket with lever bypass. Interrupt rating is 22 kAIC and the main breaker is the CSR2200. The Eaton 400 Amp 8-Space 16-Circuit Type BR Meter Socket and Main Breaker Load Center is ANSI certified and UL listed. The center is intended for use as a combination main breaker load center and meter ... 200 Amp type BW, BWH or CSR breakers, or a plug-on kit for breakers less than 100 Amp ... T4 G9 Bi-Pin Base Dimmable Decorative Halogen ...Hello, As all main electric panels for 2 meter sockets (400 amp incoming 1 phase, 240 v to two 200 amp meter sockets for service two office suites) are back … Price: $980.00 ea. Available: Available. Leviton 1R277-81 1Ph 2W 277V Meter Leviton 1R277-81 1Ph 2W 277V Meter. Qty. Price: $461.22 ea. Available: Available. Milbank U6229-X-400-K7L 400A Meter Main Milbank U6229-X-400-K7L 400A Meter Main. Qty. Price: $5,195.00 ea. What is the correct way to do a 400 amp service with 2 200amp panels? Or a 600 amp with 3 200amp main breaker panels? ... Irreversible and sized accordingly. The equipment ahead of the Service Disconnects still needs to be bonded. OR Multiple other variations... mbrooke Batteries Included. ... I know of only one triple lug meter base for …The lugs act as a 400 amp meter base with lugs. ... The possibility of running a 400 amp with 2 200 amp panels or not will be better understood with the help of the local electric code. ... You can either use 2 200 amp main disconnect panels or a 200 amp sub-panel with a main panel. ...The Siemens 400 Amp 30-Space 42-Circuit Combination Meter Socket and Main Breaker Load Center has a ring-type meter and is intended for use in underground service applications. The unit features a factory-installed, 200 Amp main breaker with a provision for a field-installed, 200 Amp maximum main disconnect (disconnect not included).The Square D 100 Amp Residential Ringless Meter Socket with horn bypass surface mounts to provide for a dual electric meter. It accommodates multiple wiring configurations for A size hub provision in the top end wall and a 2-1/2 in. maximum knockout in the bottom end-wall. This electrical meter box uses an aluminum bus, is single phase, three wires, …Vortex intercepts high-grade silver with goldNew target discovered east of BrimstoneCentral and Camel zones convert waste to mineralizationWINNEMU... Vortex intercepts high-grade s...Apr 18, 2009 · Speedy Petey. Maybe your local codes prohibit this but it is a VERY common installation everywhere else. A 320/400A meter pan with dual lugs on the load side, to two 200A main-breaker panels fed in parallel. In fact you can have up to SIX main breaker panels before a main disconnect is needed. Indices Commodities Currencies StocksUnfused wires and disconnects. The service conductors from meter to first disconnect are totally unfused. If you stick a nail through them, you can get up to a 10,000 amp dead short - possibly 22,000 amps depending on power company rules. That's approximately the impact energy of the Vulcan cannon on the F-15.The Siemens 400 Amp 30-Space 42-Circuit Combination Meter Socket and Main Breaker Load Center has a ring-type meter and is intended for use in underground service applications. The unit features a factory-installed, 200 Amp main breaker with a provision for a field-installed, 200 Amp maximum main disconnect (disconnect not included).Indices Commodities Currencies StocksBlow out as hard and fast as you can. You want to move the marker as far as you can with your breath, so concentrate on exhaling forcefully and quickly. Blow out as hard and fast a...The meter main has provision for two 200 amp main breakers. Those are your outside disconnects as required by code. From one main breaker feed your mechanical room in the house. The other 200 amp breaker feeds the shop. In both cases you will need to use 4 wire feeders, since once past the meter main your panels become sub-panels.Jul 22, 2020 · Finishing up the wiring for the electrical Aug 7, 2023 · You can run a 320 amp service with 2 200 amp panels. It has to be either two separate disconnects or a sub-panel with one main disconnect. Running with a sub-panel is cheaper than using two separate disconnects. The 320 amps is a service ideal for residential 400 amp meter sockets. The Siemens 400 Amp 8-Space 16-Circuit Combination Meter Socket Load Center is suitable for overhead or underground service applications. The combination unit is NEMA 3R rated for outdoor use and is intended for use as service entrance equipment. The center is single phase and features a lever-operated bypass with jaw tension release.I'm planning to feed two 200 amp main breaker panels from a 400 amp fused disconnect (Main disconnect after the meter provided by the building). If I ran all the …Restoration and Rewiring of 100 year old post lamps. Lighted shower niches & seat. 400 Amp Residential Service. Converted grain bin to outdoor bar.May 3, 2022 · For 200-amp sub-panel In the case of underground service, a minimum of 1.5 inches of schedule 40 or 80 PVC conduit is required for copper wire or #4/0 AWG for aluminum and copper-clad wire. You will also require a 250 kcmil-gauge copper wire. Be sure to have the proper wire size of 200 amp. A two-lug meter base has two neutral and two hot connection points on the service side. This allows two separate service lines to be attached to the meter base safely and comply with some electrical codes. ... 400 Amp Service Panel: 200 Amp Main Disconnect with Sub-panel: Two 200 Amp Main Disconnects: Service Panel Costs: …The construction allows for the 8/16 circuits inside the panel to feed exterior loads while also providing the ability to feed up to 2 more load centers from this panel. The 2nd main breaker provision will accept the QNR type (150, 175, or 200 Amp) and QP type double pole breakers (60, 70, 80, 90, 100, or 125 Amp).Net metering is explained in this article. Learn about net metering at HowStuffWorks. Advertisement You've seen the dire warnings on the news about shrinking energy resources and i...If you are a homeowner or business owner, you may have come across the term “double lug meter base” while researching your electrical system. A double lug meter base is an electric...The 400 amp house panel unit is ideal for larger homes as well as apartments, condominiums, club houses or common areas that require meter breakers. Includes 1 ringless meter socket with lever bypass. Interrupt rating is 22 kAIC and the main breaker is the CSR2200.Watch this video to find out about the Ryobi Power Usage Meter, which allows you to see how much power appliances and other electrical devices are using. Expert Advice On Improving...Siemens 400 AMP Main Electrical Panel Service Meter Socket MC3042B1400FD. $2,78800. FREE delivery May 14 - 16. Or fastest delivery Tue, May 14. Only 1 left in stock - order soon.The Square D 200 Amp Residential Ringless Meter Socket with no bypass surface mounts to provide for a single electric meter. It accommodates multiple wiring configurations for A size hub provision in the top end wall and a 2-1/2 in. maximum knockout in the bottom end-wall. This electrical meter box uses an aluminum bus, is single phase, three wires, and …Whether a building is powered by overhead lines or underground feeder cable, you can use this GE PowerMark Gold 200 Amp 4-Space 8-Circuit Ring less Meter Socket Combination Load Center. It is approved for use in Florida Meter Group areas. This unit is built to withstand the toughest environments.SCHNEIDER ELECTRIC 600-Volt 400-Amp 3-Point Nema-3R HU365R Switch Nonfusible Hd 600V 400A 3P Nema3R. 1. $2,88631. List: $3,217.92. FREE delivery May 16 - 20. Or fastest delivery Wed, May 15.The simplest conversion formula to convert watts to amps is based on the formula for amps, which is power (in Watts) divided by Volts. This is written as I(Amps) = P(Watts) / V(Vol...Aug 7, 2023 · You can run a 320 amp service with 2 200 amp panels. It has to be either two separate disconnects or a sub-panel with one main disconnect. Running with a sub-panel is cheaper than using two separate disconnects. The 320 amps is a service ideal for residential 400 amp meter sockets. Meter Combinations. Siemens provides a range of meter combinations including a line of SOLAR ready meter combinations. Siemens meter combinations are built for safety, easy installation, long term quality and sustainability. Learn more. Contact.This Siemens 200 Amp Ringless Meter Socket is UL Listed for service entrance use. The 40405-025F is intended for use as a meter socket for overhead or underground service applications. This ANSI-certified unit includes 350 kcmil lay-in lugs and 1 installed 36503, 14-2/0 ground lug.Find meter sockets at Lowe's today. Shop meter sockets and a variety of electrical products online at Lowes.com. ... Eaton GE Murray Siemens 5 4 1 2 3 125 135 150 200 225 320 400. 56 products in Meter Sockets. Sort By. Sort By. Compare. Siemens 200 1 Gang Ringless Overhead/Underground Meter Socket ... 200 1 Gang Ringless …Overview. The 400 amp house panel unit is ideal for larger homes as well as apartments, condominiums, club houses or common areas that require meter breakers. Includes 1 …Meter Combinations. Siemens provides a range of meter combinations including a line of SOLAR ready meter combinations. Siemens meter combinations are built for safety, easy installation, long term quality and sustainability. Learn more. Contact.Open Box but new 320 / 400 Amp Meter Base/Socket Non UL Single Phase Ringless. 100% Rating. 100+ sold! Returns OK. Free Same Day Ship! $404.48. or Best Offer. ... New Listing 2 Pack Milbank 200 Amp Meter Socket Base Repair Lug Assembly. $68.99. Free shipping. ⚡ Siemens 4-Gang 1200A 125 Amp RINGLESS BYPASS Power Mod …Meter Pak, 2 Socket, 200 Amp, 4 Jaw, 400 Amp Bus, Ringed, 240 Volt AC, No Bypass, NEMA 3R, 1-Phase Also known as: 785901410409, MP42200 SpecificationsEATON U4042MCC 400/320 AMP meter combo with two 200A main breakers / service disconnects. UL rated and made in USA. See my other listings for both ring and ringless …When you make a new account for any sort of web site or service, there’s usually a helpful-looking meter to tell how strong the password you came up with is. Don’t listen to those ...EATON U4042MCC 400/320 AMP meter combo with two 200A main breakers / service disconnects. UL rated and made in USA. See my other listings for both ring and ringless type meter socket / meter base. You are welcome to pick it up locally to save shipping :-) and of cause inspect the item in person. Please contact us for pickup arrangements. …Indices Commodities Currencies StocksThe National Electrical Code (NEC) doesn’t prohibit installing two 200 Amp panels where 400-amp service is delivered to the residence. There are code differences …Siemens MC3042S1400SC 400-Amp 30-Space 42-Circuits Meter Solar Load Center Combination. $2,75000. FREE delivery May 16 - 20. Or fastest delivery Wed, May 15. Only 6 left in stock - order soon. More Buying Choices.Sep 3, 2022 ... 400 AMP residential ELECTRIC SERVICE using TWO parallel 200 AMP service ENTRANCES (076) ... How To Add An External Electrical Disconnect To Your ...Finishing up the wiring for the electricalThe Siemens 400 Amp 30-Space 42-Circuit Combination Meter Socket and Main Breaker Load Center has a ring-type meter and is intended for use in underground service applications. The unit features a factory-installed, 200 Amp main breaker with a provision for a field-installed, 200 Amp maximum main disconnect (disconnect not included).Main Disconnect: (2) 200 Amp, 2-Pole, 10 kAIC Breaker. Includes: Manual Circuit Closing Bypass.***Overhead Kit Available: CK8326***. Eaton’s B-Line series meter breakers …400 amp service/ grounding and bonding. peco are bringing direct burial wires underground to my meter socket, I am going pipe into the bottom of my 320 meter socket. I then will have 2 200 amp disconnects one on left of meter socket and one on right, I am going to have a double lug in my meter and run 4/0 to my disconnects, then …Usually they use a 320 or 400 amp meter base with all the connections in there. Then they run feeds straight to two seperate 200 amp distribution panels. Also, if the cable distance is more than 10 feet they will put two 200 amp disconnect boxes next to the meter panel. Here’s a 320/400 setup with the exterior disconnects in seperate 200 amp ...I'm planning to feed two 200 amp main breaker panels from a 400 amp fused disconnect (Main disconnect after the meter provided by the building). If I ran all the …Meter Mains Compliant with NEC 2020. As NEC 2020 starts to be adopted across the country, single- and two-position residential meter sockets will need an emergency disconnect. Milbank offers multiple meter mains that can serve as the right solution for your project. Several meter mains with load centers are shown here that meet NEC 2020 ...Milbank 400/ 320 Amp Meter Socket Base & (2) 200A Siemens Disconnects UL Listed. Opens in a new window or tab. 36" outdoor Trough 2-2" hubs, 2-2" Nippels, 3 twin lugs. Brand New. ... Siemens 400 Amp Meter combo base With 2 200 Amp Breakers NEW MM0404B1400RLM. Opens in a new window or tab. Brand New. $3,300.00. alexantru …If you have 2/0 Cu from the meter base to each 200 amp panel, even though it's widely accepted it is at times turned down with reason. It is a 175 amp conductor and the 310.15(B)(7) rule that allows it on a 200 amp panel only applies when then conductor is supplying the the entire load of the dwelling.A two-lug meter base has two neutral and two hot connection points on the service side. This allows two separate service lines to be attached to the meter base safely and comply with some electrical codes. ... 400 Amp Service Panel: 200 Amp Main Disconnect with Sub-panel: Two 200 Amp Main Disconnects: Service Panel Costs: …This Siemens 200 Amp Ringless Meter Socket is UL Listed for service entrance use. The 40405-025F is intended for use as a meter socket for overhead or underground service applications. This ANSI-certified unit includes 350 kcmil lay-in lugs and 1 installed 36503, 14-2/0 ground lug.Many Atlanta residents complain about the high cost of water. According to the Atlanta Journal-Constitution, Atlanta residents pay 108 percent more than New York City residents and...Eaton 1011619CH 320 Amp Single Phase Meter Base Socket Ringless Lever Bypass 4 Terminal Factory Installed Lugs MEG Approved $1,393.50 $ 1,393 . 50 FREE delivery Wed, May 22

Generator Transfer Switches | Self Contained | 100 & 200 Ampere | Single Phase | W/O Meter Socket | 600 VAC. Switches are double pole/double throw with center off position. Add suffix “R” to catalog number for 50 Amp locking-type male receptacle installed & prewired to auxiliary connectors.. Food lebanon tn

400 amp meter base with 2 200 amp disconnects

disconnect to improve safety for those working closely with the equipment. The meter mains are offered in non-EUSERC and EUSERC configurations. Features: • 2 service disconnects in separate compartments • Meter socket rating: 320A continuous, 400A Max. • 1 phase, 3 wire, 120/240V • Applicable for overhead & underground or underground Overview. The Square D 400 Amp 30-Space 40-Circuit Combination Meter Socket and Dual Main Breaker Load Center is suitable for use as a combination service entrance device (CSED) and is a ring-type unit. It is suitable for underground service applications. Accommodates plug-on secondary surge arrestor, and features a plug-in design for easy ...Since then i had my PUD engineer come out and after a couple weeks the solution they came upwith was to install my 320 amp meter base and two 200 amp disconnects at the pole and then run an additional run of conduit to the house so my question now is do i need to pull the 500/500/350 and install 2 runs of 4 wire feeder to the panels at the ...Meter Mains Compliant with NEC 2020. As NEC 2020 starts to be adopted across the country, single- and two-position residential meter sockets will need an emergency disconnect. Milbank offers multiple meter mains that can serve as the right solution for your project. Several meter mains with load centers are shown here that meet NEC 2020 ...t nipple 2 2 1/2" 12 WeatherproofWeatherproof disconnectt AmpAmp 13; Breaker or fuse 2 200 Amp: 14: Treated 4 x 4 post 2 8' 15; Treated lumber As required: A. Secure meter …All manufacturers make an all in one 400 amp meter combo for residential. They are usually rated as 320 amp but they are really 400 amps non continuous load and 320 continuous load. Cutler Hammer , GE , Sq.D and Siemens all make them. They have 2 spaces inside for 2- 200 amp breakers and can also have some other spaces available …Meter Mains with Emergency Disconnect UL Listed | 100-200 Amps Features • 100-200 Amps • Horn bypass option available when ordered with -KK suffix • Ringless meter socket • Main breaker • Overhead/underground entry on U5844; overhead only on ... 2 U5844-PXL-200 200 OH/UG C.P. #6-350 41 ...Meter Combinations. Siemens provides a range of meter combinations including a line of SOLAR ready meter combinations. Siemens meter combinations are built for safety, easy installation, long term quality and sustainability. Learn more. Contact.UNSPSC. 39121101. Product Overview. The Siemens 400 Amp 8-Space 16-Circuit Combination Meter Socket Load Center is suitable for overhead or underground service applications. The combination unit is NEMA 3R rated for outdoor use and is intended for use as service entrance equipment. The center is single phase and features a lever …To meet this requirement, Milbank developed 400 Amps meter mains that include a single 400 Amps breaker disconnect and a meter socket in one enclosure. Our meter mains are good fits for large residential and commercial applications such as retail, office buildings and restaurants. Features: The wall-hanging bracket and side bussing are features ...Eaton's House Panel offers fast, easy and safe installation. These 400A units are ideal for larger homes that require meter breakers. Available in CH and BR styles, these service entrance devices consist of a meter socket and a distribution section. In response to contractor feedback, these panels have been redesigned with a focus on flexibility, …Place the mouthpiece in your mouth, between your teeth. Close your lips around it. Do not put your tongue inside the hole or block the vents in the back. Place the mouthpiece in yo...BS2M-V METER BASE 200AMP DOUBLE LUG Oversize Enclosure Subfeed on Load Side. 4 jaw 200 A. Overhead hub opening. Technical Specifications Technical Specifications ... 200 AMPERE : Wire Size: 6 AWG TO 250 KCMIL (LINE), 12 TO 1/0 AWG (LOAD) Voltage Rating: 600 V : Size: 12 INCH W X 5 7/16 INCH D X 17 1/8 INCH H :Watch this video to find out about the Ryobi Power Usage Meter, which allows you to see how much power appliances and other electrical devices are using. Expert Advice On Improving...Overview. The Square D 400 Amp 30-Space 40-Circuit Combination Meter Socket and Dual Main Breaker Load Center is suitable for use as a combination service entrance device (CSED) and is a ring-type unit. It is suitable for underground service applications. Accommodates plug-on secondary surge arrestor, and features a plug-in design for easy ...Electrician, Contractor, Inspector. May 27, 2021. #7. If you have a 400 amp meter you could put 2 200 amp service disconnects next to the meter. You will then have feeders that can go to MLO panels anywhere you want. Not open for further replies. Taking over a job and the service doesn't seem legal to me. What they have is a 400 (320) ….