Heat pump 410a pressures - Last updated: 27 Jun, 2017. Heat Pump: Heating. Re: High Discharge Pressure / High Head Pressure. As the system runs in the heating mode, the discharge pressure exceeds the normal operating pressure. R22 System. Normal Head Pressure = 175 - 250 psig. High Head Pressure = Above 275 psig. R410A System. Normal Head Pressure = 225 - 350 …

 
Sep 4, 2021 ... 27:56. Go to channel · Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips! AC Service Tech LLC•1.3M views · 15:25. Go ...... How to get headmistress earrings

The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the …Break the vacuum on the system and supply liquid R-410A to the liquid line or receiver port. Weigh in the initial charge and ensure a proper vacuum was achieved. Adjust sensors or set points to operate the compressor continuously while charging the system. Add refrigerant to allow the discharge pressure to rise to 325-420 psig.Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...Nov 2, 2003 · Recovery Of 410A Standard recovery procedures for R-410A remain unchanged. The only difference is the necessity to use a recovery machine and cylinders approved for the higher pressures of R-410A. Charging Since R-410A has a slight (0.3 degree) fractionation, it, like all other 400 series refrigerants, must be charged in the liquid state. Heat Pump. R-410A. Installation instructions manual. Rheem R-410A Installation Instructions Manual. Prl-jec series two-stage heat pump outdoor units. Also See for R …Failure to follow this warning could cause personal injury, death and/or equipment damage. R−410A refrigerant systems operate at higher pressures than standard R−22 systems. Do not use R−22 service equipment or components on R−410A refrigerant equipment. 506 01 2301 00 1/21/15.View and Download Goodman R-410A installation manual online. R-410A OUTDOOR SPLIT-SYSTEM HEAT PUMP, 13 SEER & 14.5 SEER 1.5 TO 5 TONS – 1 & 3 PHASE. R-410A heat pump pdf manual download. Also for: Thgd series, Thgf series, Ghgd series, Thjd series, Thjf series, Yhjd series, Yhjf...Let's get started and see what we can do.Most manufacturers recommend charging by super heat and subcoolimg rather than pressures alone,and will vary slightly by manufacturer but as a rule low side of about 110 and high side about 280at 70 degree ambient. This will of course increase as temp warms up.ON an 85 degree day,probably 130 to 135 and ...Pardo et al. [34] tested on an R-410A heat pump the refrigerants DR-5A and L41-2. Increments of 3–6% were found in terms of cooling capacity using DR-5A, while for the system operating with L41-2, the cooling capacity was reduced by 1–7%. Burns and Chen [21] evaluated drop-in tests on a split heat pump with five R-410A alternative ... pressures and refrigeration capacity than R-22. The compositions of Freon™ 407C and Freon™ 410A are as follows: HFC-32 HFC-125 HFC-134a Freon™ 407C (R-407C), wt% 23 25 52 Freon™ 410A (R-410A), wt% 50 50 — Because Freon™ 407C and Freon™ 410A are mixtures of HFCs, they have zero ODP. Table 1 lists the chemical names and formulae of the Feb 20, 2023 ... The operating pressure of 410A on an 85 degree day is 254.6 psig. Example 3: What are 410A pressures on a 70 degree day? The operating pressure ...Equipment designs must accommodate its higher pressures. It cannot be retrofitted into R-22 heat pumps. Physical Properties: R-410A has an atmospheric boiling ...R410A Pressure Temperature Chart (In Fahrenheit) Printable PDF Temp er atu r e (° F ): R410A P r essu r e (p si g ):-60 ° F 0. 9 psi g-55 ° F 1. 8 psi g-50 ° F 4. 3 psi g-45 ° F 7. 0 psi g-40 ° F 10. 1 psi g-35 ° F 13. 5 psi g-30 ° F 17. 2 psi g-25 ° F 21. 4 psi g-20 ° F 25. 9 psi g-18 ° F 27. 8 psi gR410A Pressure Temperature Chart (In Fahrenheit) Printable PDF Temp er atu r e (° F ): R410A P r essu r e (p si g ):-60 ° F 0. 9 psi g-55 ° F 1. 8 psi g-50 ° F 4. 3 psi g-45 ° F 7. 0 psi g-40 ° F 10. 1 psi g-35 ° F 13. 5 psi g-30 ° F 17. 2 psi g-25 ° F 21. 4 psi g-20 ° F 25. 9 psi g-18 ° F 27. 8 psi gMay 24, 2016 ... HVAC R22, 410A Refrigerants! Checking the Charge- Vapor/Suction Operating Pressures, What is Too Low! P/T Chart on the Manifold Gauge Set is ...How to Read an R-410A PT Chart. 1. Identify Desired Temperature. Determine Temperature: Choose the required temperature for your system based on its application or specific needs. 2. Find Corresponding Pressure. Locate on Chart: Find the selected temperature on the P-T chart and note the corresponding pressure in psig (pounds per …Refrigerant R-410A Pressure Temperature Chart - R410A is an HFC and is commonly used in residential and light commercial HVAC equipment for air conditioners.Pumps are devices used to move liquids like water and fuel. Hydraulic pumps use liquid to convert mechanical energy into pressure and flow. Here’s a brief look at how hydraulic pum...R410A Systems Run at a Different Pressure. Compared to an R22 system, an R410A air conditioner runs at a higher pressure. These systems operate at about 130 pounds per square inch (psi). In AC mode, an R22 evaporator coil will run at about 70 psi. ... Matching an R22 coil with an R410A condensing unit is not possible with an outdoor …Example 3: What are 410A pressures on a 70 degree day? The operating pressure of 410A on a 70 degree day is 201.5 psig. Example 4: What are 410A pressures on a 65 degree day? The operating pressure of 410A on …4. Post Likes. Very high suctuion and head pressure on heating mode. Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both ...May 24, 2016 ... HVAC R22, 410A Refrigerants! Checking the Charge- Vapor/Suction Operating Pressures, What is Too Low! P/T Chart on the Manifold Gauge Set is ...How to Read an R-410A PT Chart. 1. Identify Desired Temperature. Determine Temperature: Choose the required temperature for your system based on its application or specific needs. 2. Find Corresponding Pressure. Locate on Chart: Find the selected temperature on the P-T chart and note the corresponding pressure in psig (pounds per …It is a clear, colorless, non-toxic and non-irritating liquid. R-410A is a 50:50 blend of R-32 and R-125. The boiling point at atmospheric pressure is -62.9°F. A few of the important principles that make the refrigeration cycle possible …The tech and his apprentice did the usual things like pressure washing out door condensor etc. They hooked up the gauges and to check pressures. They felt it needed a smidgen of 410A. After that I didn't run the system for week and a half until the weather turned much warmer and much more humid. The heat pump went into cooling mode when I fired ...What are the normal operating pressures for 410a high and low side in a 2 ton heat pump? 125 PSI for low and 365 PSI for high, the high can vary as the outdoor temperature does, basically on an 85 degree day you should see about 365. It can get up to 400 PSI on a 95 degree day.And 500 PSI on a 110 degree day.The residential water well owner should set the pressure in a bladder tank at 2 pounds per square inch lower than the cut-on pressure for the well pump. A tire pressure gauge place...R-410a heat pump 60hz (264 pages) Air Conditioner DAIKIN R410A Series Installation Manual (177 pages) ... (A1P) in the outdoor unit to stop the additional • R-410A installations to withstand the pressure and to pre- refrigerant charge operation. vent foreign materials from mixing into the system.Break the vacuum on the system and supply liquid R-410A to the liquid line or receiver port. Weigh in the initial charge and ensure a proper vacuum was achieved. Adjust sensors or set points to operate the compressor continuously while charging the system. Add refrigerant to allow the discharge pressure to rise to 325-420 psig.View and Download Rheem R-410A installation instructions manual online. PRL-JEC Series two-stage heat pump outdoor units. R-410A heat pump pdf manual download. Also for: Prl-jec series, 024jec, 036jec, 048jec, 060jec.Here we will learn the R410A Pressure-Temperature Chart. R410A is very commonly used refrigerant that is known as AZ-20”, “Genetron R410A”, “Puron. It is patented by Honeywell. It is mostly used freon in AC systems and works as a replacement for R22. Here we will make an R410A Pressure-Temperature Chart that will help you find its ...Temp(°F) Liquid Pressure (psi) Vapor Pressure (psi) -49. 5.5. 5.4. -48. 6.0. 5.9.Lennox Learning Solutions teaches you what causes high head pressure on a heat pump in the heating mode.There is several factors that can cause hight pressur...Digital Fieldpiece Gauges: https://amzn.to/2LFjNnKR410A Equipment: https://amzn.to/2xv6AG5My Favorite Tool: https://amzn.to/3NIFJuOTools We Recommend: https:...View and Download Rheem R-410A installation instructions manual online. PRL-JEC Series two-stage heat pump outdoor units. R-410A heat pump pdf manual download. Also for: Prl-jec series, 024jec, 036jec, 048jec, 060jec. It is a clear, colorless, non-toxic and non-irritating liquid. R-410A is a 50:50 blend of R-32 and R-125. The boiling point at atmospheric pressure is -62.9°F. A few of the important principles that make the refrigeration cycle possible are: heat always flows from a warmer to a cooler body. A/C or Heat Pump Compressor High Head Pressure Diagnostic FAQs. ... R410 low side typical pressure would be about 120 psi and the high side between 410-420 psi. Your high side is a little low. I would start by checking the TXV / TEV adjustment. On 2019-02-11 by Mike. I have a trane package unit that goes out on high head it did it once …Getting no guage pressure on York heat pump in cooling mode but compressor is running. Is compressor bad? On 2020-04-08 by (mod) - Causes of a refrigerant pipe leak due to cracking ... I have a 3 ton 410a Lennox with correct suction pressure however my high side pressure is way low. Pressures are 120headover 118 suction low side. What would be ...Apr 15, 2021 · Trying to diagnose a 2 year old Amana heat pump with high suction and discharge pressures in heat mode. ASZ 16 SEER OD unit matched up with an ARUF Goodman piston air handler. Both are 2 ton 410A units. 10kw heat kit and lineset is about 20ft long. HEAT MODE Unit is tripping out on high head(600psi). Goodman Charging Chart | Heat pump Pressures in heating mode 410a | GSX13 | GSX | GSX 14 | GSX 16 | Goodman Refrigerant Charging Chart | 410a piston charging. Services. 24 Hours Ac Repair Near Me; Heating and Cooling Near Me; Air Conditioning; Ac Repair; HVAC. Residential HVAC; Air Conditioning; Areas We Served. Houston Tx;Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20°-25° suction saturation below outdoor ambient.The thermometer shows us that the superheated R-410A vapor is at 54°F temperature. Now we can calculate R-410A superheat: Superheat (R-410A) = 54°F – 51°F = 3°F. In this case, we have a dangerously low 3°F superheat. This presents a risk that the suction line will deliver liquid R-410A to a vapor-only compressor and flood it.Digital Fieldpiece Gauges: https://amzn.to/2LFjNnKR410A Equipment: https://amzn.to/2xv6AG5My Favorite Tool: https://amzn.to/3NIFJuOTools We Recommend: https:...Brand Model Compatibility: NXH5 R-410A Split System Heat Pump. Product Type: Low Pressure Limit Switch. 0. Shop for Low Pressure Switch for NXH5 R-410A Split System Heat Pump from International Comfort Products At Ferguson. Ferguson is the #1 US plumbing supply company and a top distributor of HVAC parts, waterworks supplies, and … Page 1 16~22 SEER, Inverter Unit 9,000 to 36,000 BTU/Hr Single Split Cooling only 4MYW8-A 4TYK8-A Heat pump 4MXW8-A 4TXK8-A June 2012... Page 2: Warnings And Cautions R-410A, please contact your Failure to use R-410A approved service equipment could result in standard equipment exploding under R-410A higher pressure which could result in death ... A Carrier 15 Seasonal Energy Efficiency Ratio heat pump has a higher energy efficiency rating than a Carrier 14 Seasonal Energy Efficiency Ratio heat pump. The heat pump with a hig...A discussion around dt and how it affects heat pump performance. Underfloor heating and radiators with TRV valve Refrigerant charge quantity for air conditioners & heat pumps: This air conditioning repair article series discusses the the diagnosis and correction of abnormal air conditioner refrigerant line pressures as a means for evaluating the condition of the air conditioner compressor motor, which in turn, is a step in how we evaluate and correct lost or reduced air conditioner cooling capacity. Both older R-22 and R-134 operate at lower pressures than R-410A. R22 Refrigerant Pressure Rules of Thumb Typical Off, Low, High side R22 Pressures & Temperatures. ... When you measure heat pump or cooling system pressures makes as much difference as where you measure it. When an air conditioning or heat pump system has turned off and …View and Download Rheem R-410A installation instructions manual online. PRL-JEC Series two-stage heat pump outdoor units. R-410A heat pump pdf manual download. Also for: Prl-jec series, 024jec, 036jec, 048jec, 060jec. In this video we go through the basics of checking a heat pump charge in heating. It can be tricky but its pretty simple if you do this..Title music:Music: B... Refrigerant R-410A Pressure Temperature Chart - R410A is an HFC and is commonly used in residential and light commercial HVAC equipment for air conditioners.Re: Heat pump overcharged in heating mode. . Depending on the make and quality of the thing the the outside heat exchanger is. split into 2/3 and 1/3, so when the thing is in cooling mode the outside cond. uses both 2/3 and 1/3 of the cond together to get total heat rejection but in heat. pump mode the outside heat exchanger (now evap) only ...Split-SyStem heat pump up to 14 SeeR / R-410a Cooling Capacity: 17,400 - 55,000 Btu/h heating Capacity: 15,200 - 59,000 Btu/h DZ13SA * Complete warranty details available from your local dealer or at www.daikincomfort. com. To receive the 6-Year Unit Replacement Limited Warranty and 12-Year PartsIt is stamped 4lbs 15oz. for the manufactures charge of 410A. 4. Last check by the tech from the company that installed it before going out of warranty was High side 275 psi, high side temp 70F, Low side psi was 115 Low side temp 50. This calculates to Super Heat of 12 more or less.In this HVAC Training Video, I Show How to use the Charging Jacket to Measure the Refrigerant Charge on a Heat Pump or AC when the Outdoor Ambient Temperatur...Maybe my instructor said that to check the charge level on a heat pump in heat mode, the subcooling must be between 08-12 degrees F, and the delta T must be 16-20. I had 41 degrees Fahrenheit of subcooling. If the subcooling must be between 08-12 degrees F in heat mode, then my unit was overcharged. But the last time I checked my … Page 1 16~22 SEER, Inverter Unit 9,000 to 36,000 BTU/Hr Single Split Cooling only 4MYW8-A 4TYK8-A Heat pump 4MXW8-A 4TXK8-A June 2012... Page 2: Warnings And Cautions R-410A, please contact your Failure to use R-410A approved service equipment could result in standard equipment exploding under R-410A higher pressure which could result in death ... Advertisement All of the hydraulic systems on a backhoe get their hydraulic pressure from a hydraulic pump. There are two types of pumps in common use: In a gear pump, a pair of in...R−410A systems operate at higher pressures than standard R−22 systems. Do not use R−22 service equipment or components on R−410A equipment. Ensure service equipment is rated for R −410A.! WARNING Refrigeration systems contain refrigerant under pressure. Extreme caution should be observed when handling refrigerants.Applications: Air conditioning equipment and heat pumps. Only for newly manufactured equipment, not for retrofitting R-22 systems Performance: Presures are 60% higher than R-22, therefore should be used only in new equipment Lubricant Recommendation: Compatible with polyolester lubricant Retrofitting: For new equipment only Temp (˚F) R-410A ...Blood pressure is a measurement of the force exerted against the walls of your arteries as your heart pumps blood to your body. High blood pressure (hypertension) is an increase in... = Heat capacity at constant pressure in kJ/(kg)(°C) C v = Heat capacity at constant volume in kJ/(kg)(°C) v s = Velocity of sound in m/sec The gas constant, R = 8.314 J/(mole) (K) for Freon™ 410A, R = 0.11455 kJ/kg·K One atmosphere = 101.325 kPa Reference point for enthalpy and entropy: h f = 200 kJ/kg at 0 °C s f = 1 kJ/kg·K at 0 °C ... R-410a heat pump 60hz (264 pages) Air Conditioner DAIKIN R410A Series Installation Manual (177 pages) ... (A1P) in the outdoor unit to stop the additional • R-410A installations to withstand the pressure and to pre- refrigerant charge operation. vent foreign materials from mixing into the system.The refrigerant of the heat pump is compressed in the compressor with a pressure ratio of 3.5, where the expansion pressure is 6.5 bar, and this is within the typical operation ranges of the ...psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114As an example, Trane includes a pressure curve chart with many heat pump condensing units. Be sure to use the scale all the way to the right that says heat mode. ... does not work on an R-410A system. A more applicable guideline is 20˚-25˚ suction saturation below outdoor ambient. This means if it is 50˚ outside, the suction saturation ...An R-22 Replacement for New ACs and Heat Pumps. Freon™ 410A (R-410A) refrigerant offers higher cooling capacity and significantly higher pressure than R-22 ...The typical 410a pressures on a 95 degree day are as follows; Liquid pressure: 296.4 psi. Vapor pressure: 295.5 psi. See all other pressures for R410 on different temperatures of the day from -49°F to 150°F below.Let's get started and see what we can do.Most manufacturers recommend charging by super heat and subcoolimg rather than pressures alone,and will vary slightly by manufacturer but as a rule low side of about 110 and high side about 280at 70 degree ambient. This will of course increase as temp warms up.ON an 85 degree day,probably 130 to 135 and ...Feb 13, 2022 ... How to diagnose, remove & replace a bad thermostatic expansion valve in a heat pump condenser.-40-39-38-37-36-34-33-32-31-30-29-28-27-26-24-23-22-21-20-19-18-17-16-14-13-12-11-10-9-8-7-6-4-3-2-1: 0: 1: 2: 3: 4: 6: 7: 8: 9: 10: 11: 12: 13: 14: 16: 17: 18: 19 ... system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3. If you’re considering upgrading your home’s heating and cooling system, you may have come across the term “heat pump.” A heat pump is a highly efficient and versatile system that c...An air conditioner or heat pump using R-410A refrigerant may operate at pressures exceeding 600 psi. A typical Carrier HVACR unit incorporates a high-pressure safety switch that operates at 610 psi and a low pressure (loss of refrigerant detection safety device) that operates at about 20 psi.Feb 20, 2023 ... The operating pressure of 410A on an 85 degree day is 254.6 psig. Example 3: What are 410A pressures on a 70 degree day? The operating pressure ...Jan 4, 2017 · R410a unit heat pump. Get to call and unit wont turn on. Customer stats unit runs for five minutes with hot air coming out the starts blowing cold. Check all switches and limits. Find the lower pressure switch open. Jump it go see if unit runs and see what the charge looks like. Unit is running 300/80 in heat mode. A new air-conditioner using r-410a is used in heat pump mode. the high410a conditioner clearly homeworklib 410a pressureGoodman 410a charging chart. 410a gyazo saturatedR410a charging chart Charging 410a refrigerant pump hvac hvacrschoolI'm looking for a freon charging chart for a trane heat pump model. Check Details View and Download Rheem R-410A installation instructions manual online. PRL-JEC Series two-stage heat pump outdoor units. R-410A heat pump pdf manual download. Also for: Prl-jec series, 024jec, 036jec, 048jec, 060jec. Nov 2, 2003 · Recovery Of 410A Standard recovery procedures for R-410A remain unchanged. The only difference is the necessity to use a recovery machine and cylinders approved for the higher pressures of R-410A. Charging Since R-410A has a slight (0.3 degree) fractionation, it, like all other 400 series refrigerants, must be charged in the liquid state. Refrigerant R-410A Pressure Temperature Chart - R410A is an HFC and is commonly used in residential and light commercial HVAC equipment for air conditioners.assembled, piped and wired at the factory to provide a single-piece. unit for shipment and rigging. Each unit is pressurized with a holding. charge of refrigerant R-410A for storage and/or shipping. The compact design, clean styling, small footprint, and quiet operation. make these condensing units and heat pumps suitable for almost any.Let's get started and see what we can do.Most manufacturers recommend charging by super heat and subcoolimg rather than pressures alone,and will vary slightly by manufacturer but as a rule low side of about 110 and high side about 280at 70 degree ambient. This will of course increase as temp warms up.ON an 85 degree day,probably …R−410A and R−22 air conditioner or heat pump. Model and serial numbers can be found on unit rating plate. Table 1—Air Conditioner and Heat Pump Model Number Nomenclature ... R−410A systems operate at higher pressures than standard R−22 systems. Do …Adding Freon to heat pump during the heat mode, Carrier Unit, winter season maintenance, 2018 HVAC TECHNICIANr-410a pressure temperature chart psig f° psig f° psig f° psig f° psig f° psig f° 12 -37.7 114 37.8 216 74.3 318 100.2 420 120.7 522 137.6 14 -34.7 116 38.7 218 74.9 320 100.7 422 121 524 137.9 16 -32.0 118 39.5 220 75.5 322 101.1 424 121.4 526 138.3

The Rheem RPKA-049JAZ heat pump is a 4-ton unit. Rheem heat pumps with 048 or 049 in the model number have a nominal cooling capacity of 48,000 British Thermal Units (BTUs) per hou.... Iowa dnr migration report

heat pump 410a pressures

Heat pumps are an energy-efficient way to heat and cool your home. They use electricity to move heat from one place to another, rather than generating their own heat like tradition...SiUS281117 Table of Contents i RZR-P, RZQ-P(9) Series Cooling Only / Heat Pump R-410A 60Hz ED Reference For items below, please refer to Engineering Data.Physical Properties: R-410A has an atmospheric boiling point of -62.9°F [-52.7°C] and its saturation pressure at 77°F [25°C] is 224.5 psig. Composition: R-410A is a near-azeotropic mixture of 50% by weight difluoromethane (HFC-32) and 50% by weight pentafluoroethane (HFC-125).Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...Split Heat Pump. Up to 15 SEER / 9.0 HSPF Performance. GSZ14. See why our customers love this unit. Customer Reviews. ... A high-pressure switch prevents the system from operating at extremely high pressures by shutting off the compressor circuit if the pressure exceeds the designated rating. When a refrigeration system operates at lower than ...Properties of R410A Refrigerant. The R410A is a type of hydrofluorocarbon (HFC) refrigerant commonly used in AC systems, heat pumps, and commercial HVAC equipment. It was developed as an environmentally friendly alternative to older freon refrigerants like R-22. It has several benefits over traditional freon refrigerants, including a lower risk ... Due to its single-component nature, R32 heat pumps use 20% less refrigerant than R410A heat pumps. Consequently, their operational costs are lower. R410A refrigerant cannot be reclaimed like R32, as the former is a blend. R410A operates at high pressures, which poses safety hazards. Physical Properties. General physical properties for FreonTM 407C and FreonTM 410A are shown in Table 3. The pressure-enthalpy diagrams for FreonTM 407C are shown in …A two-stage heat pump has a compressor which is capable of operating at a high and low speed, improving its ability to maintain the temperature in a home with greater precision. Th...How to Read an R-410A PT Chart. 1. Identify Desired Temperature. Determine Temperature: Choose the required temperature for your system based on its application or specific needs. 2. Find Corresponding Pressure. Locate on Chart: Find the selected temperature on the P-T chart and note the corresponding pressure in psig (pounds per square inch ...High Suction Pressure R-410a. i went to check an 3.5 ton a/c brand is a ICP (international comfort products) Model WAPL424A1, not cooling my pressures were low side 185 to 190 and high side was around 350 on a 107F hot day. It has a piston as a metering device and compressor was running at 11.50 amps and RLA is 17.25 amps.This long line set application guideline applies to all AHRI listed R-410A air conditioner and heat pump split system matches of nominal capacity 18,000 to 60,000 Btuh. This guideline will cover installation requirements ... pressure and temperature of the liquid line at the indoor unit must be measured to calculate subcooling atassembled, piped and wired at the factory to provide a single-piece. unit for shipment and rigging. Each unit is pressurized with a holding. charge of refrigerant R-410A for storage and/or shipping. The compact design, clean styling, small footprint, and quiet operation. make these condensing units and heat pumps suitable for almost any..